Good design EP3000series pure sine wave 12v 1500w power inverter for home use
1.Applications:
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets. Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter,
2. Features
Soft start capability for starting heavy loads
New power factor corrected (PFC) charging
Available in 1000 and 3000 watt models Utility grade, sine wave power
Durable construction for long life under extreme environmental conditions
70 AMP automatic three-stage battery charger (bulk, absorption, and float)
Battery equalization with remote temperature sensor for increased performance
Low idle current (less than 1 watt) conserves energy when no loads are present
Built-in starting control circuits for two- and three-wire generator starting systems
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging Better thermal performance allows full output power to 50° C (122° F) without de-rating High surge capacity starts more difficult loads and handles overload conditions reliably Simplified controls with a snap-on cover that protects settings from being accidentally change
MODEL | 115V Models | 230V Models | |
OUTPUT | |||
Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | 1KW;2KW;3KW;4KW;5KW;6KW | |
Output Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:'1 | ||
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
(Synchronized to Mains) | |||
Regulation (Nominal) | ±20% typical of nominal voltage | ||
Regulation | ±3% of selected output voltage (adjustable with the | ||
(Battery mode) | remote set-up software) | ||
Transfer time | Blackout 3ms typical,Brownout 1ms typical,Battery mode to Normal mode:1ms typical | ||
Over current protection | Over load alarm level 100% ~ 120% | ||
Over load shutdown level 120% ~ 190% | |||
(Adjustable by using the remote set-up software) | |||
INPUT | |||
Nominal Voltage | 110V/115V/120V Selectable | 220V/230V/240V Selectable | |
Input Frequency | 47Hz ~ 65Hz, 50/60Hz auto-sensing | ||
Efficiency (Normal mode) | 99% | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Over current protection | Re-settable over current protector:1000W~4KW | AC Fuse1000VA/2000VA,Re-settable over current protector:1000W~6KW | |
Voltage Range | 85V ~ 145V | 185V ~ 265V | |
AVR Range (2 Bucks, 2 Boosts) | Enhanced Buck: +28% of selected nominal voltage | ||
Buck mode: +10% of selected nominal voltage | |||
Boost mode: -10% of selected nominal voltage | |||
Enhanced Boost: -25% of selected nominal voltage | |||
Surge Protection | 1KW/ 2KW:416 Joules | 1KW-3KW:430 Joules | |
3KW ~ 4KW:724 Joules | 4KW-6KW:826 Joules | ||
BATTERY | |||
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
DC Voltage | 1KW/2KW:12Vdc | 1KW/2KW/3KW:12Vdc | |
2KW/3KW:24Vdc | 2KW/3KW:24Vdc | ||
3KW/4KW:48Vdc | 3KW/4KW/5KW/6KW:48Vdc | ||
Typical backup time | No Limit | ||
Charging method | Smart pulse charging with two charging modes?EQuick charging when battery | ||
is not fully charged, trickle charging when battery is 90% fully charged. | |||
Maximum charging current | 1000W 12V:35A | 1000W 24V:35A | |
2000W 12V:65A | 2000W 24V:35A | ||
3000W 24V:45A | 4000W 48V:35A | ||
5000W 48V:40A | 6000W 48V:50A | ||
Average charging | Quick charging mode:15.7V-54V maximum. | ||
voltage for each battery | Trickle charging mode:13.5V -52V(adjustable with the remote set-up software) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) | ||
Thermal protection (CPU control) | |||
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
Monitoring | Smart monitoring & warning for failed battery or open-circuit battery. | ||
Auto-detection each time when power on or every 6 days. | |||
SOLAR CHARGER | |||
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V | |
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
Charging method | Constant voltage with current limiting by PWM control | ||
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A) | |||
Protection | DC input polarity protection, DC input short circuit protection( when battery is | ||
connected), DC output over current protection | |||
COMMUNICATIONS & MANAGEMENT | |||
Standard Interface port | UPSilon2000 compatible; optional for RS232 . | ||
Optional Interface part | RJ45 (Surge protection), DB9 | ||
Control panel | LCD or LED Selectable | ||
Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
Green mode function | 1% to 14% of full load (adjustable by using the remote set-up software) | ||
(Auto-shut-off in blackout) | The default setting is OFF. | ||
Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
ENVORMENT AND SAFETY | |||
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
Relative Humidity | 5 - 95% non condensing | ||
Operating Altitude | 0 ~ 3000 meters | ||
Quality control system | ISO 9001:2000, ISO 14002-2004 | ||
PHYSICAL | |||
Appearance | Size(mm)LxWxH | 570*315*300 | |
Weight(Kg) | 1000W/18.2kg ;2000W/19.5kg ;3000W/23.5kg | ||
Size(mm)LxWxH | 755*319*288 | ||
Weight(Kg) | 4000W/35kg ;5000W/38kg ;6000W/40kg |
Nancy