V&T Company Introduction
A Knowledge-based company,V&T brings you the benefits of over 20 years of engineering experience and expertise, and the richness of its collaborations with technology leaders across the global.
V&T is one of the leading AC Drive manufacturers in China with a dedicated, CNAS-certified testing facility. Our products are tested for conformity to standards that exceeds mandatory requirements, giving you the assurance of high-quality performance. Our focus on continuous improvement ensures that our quality is on par with the best in the world. Repeat orders endorse the value that we deliver.
The reliability of our products are ensured by international test certification-CE, RoHs, SGS, and EAC .
Textile industry:
1.Reducing the rate of breakage and improving the efficiency of production
2.Specially made external heat radiator, cotton easy clean
3.Unique function of swing frequency is suitable for equipment of yarn winding
4.Rich indicaton signals: full indication, broken wire indication, power failure indication, etc.
A Knowledge-based company,V&T brings you the benefits of over 20 years of engineering experience and expertise, and the richness of its collaborations with technology leaders across the global.
V&T is one of the leading AC Drive manufacturers in China with a dedicated, CNAS-certified testing facility. Our products are tested for conformity to standards that exceeds mandatory requirements, giving you the assurance of high-quality performance. Our focus on continuous improvement ensures that our quality is on par with the best in the world. Repeat orders endorse the value that we deliver.
The reliability of our products are ensured by international test certification-CE, RoHs, SGS, and EAC .
Textile industry:
1.Reducing the rate of breakage and improving the efficiency of production
2.Specially made external heat radiator, cotton easy clean
3.Unique function of swing frequency is suitable for equipment of yarn winding
4.Rich indicaton signals: full indication, broken wire indication, power failure indication, etc.
Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Motor Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 3.5 | 6.2 | 9.2 | 14.9 | 21.5 | 27.9 | 39 | 50.3 | 60 | 69.3 | 86 | 104 | 124 | 150 | 201 | |
Braking unit | Built-in as standard | External braking unit needed | ||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Self-cooling | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |