S300 series universal variable frequency drive is a universal vector frequency converter for industrial control, mainly used to control and adjust three phase AC motor speed and torque, widely and not limited used in below regions:
Why choose Micctech variable frequency drive?
Shenzhen Micctech is a leading high-tech scientific company, dedicated in industry equipment including variable pitch servo motor, full set of control system, frequency converter and inverter, and energy saving device. Founded in 2014, Micctech now owns over 200 employees, and about 70% of them are R&D engineers.
Office & production line
Equipments used in R&D developing process and mass production
Advantages of Micctech VFDs are mainly in these sides:
1. Micctech VFD Suit for most of Asynchoronaus and synchoronause drive and support kinds of control method. For example:
Asynchoronous drive can choose No PG flux vector control, with PG flux vector control and V/F control;
For synchoronous drive, it can choose No PG flux vector control, with PG flux vector control.
2. Compatible encoder:
It support rotary transformer and ABZ incremental encoder.
3. Communication:
Modbus, CANopen and Profibus-DP.
4. Steady and reliable:
Micctech uses high-class electronic units, excellent design, conformal coating on PCBA and independent air flue, all them work together to ensure the VFD has longer life time.
5. High starting torque:
In No PG flux vector control mode, when output frequency is 0.25Hz, VFD can reach 150% rated torque; In PG flux vector control mode, when output frequency is 0Hz, VFD can reach 180% rated torque.
6. High torque precision:
In No PG flux vector control mode, torque control precision is less than 7.5%; In PG flux vector control mode, torque control precision is less than 5%.
7. Compact structure:
Book style structure saves room for whole electric cabnet. More VFDs can be installed in the same width cabinet.
Photos showing Micctech VFD inverters installed in different applications.
S300 series universal variable frequency drive has 6 sizes. Details are showed as below table:
Micctech VFD power various from 5.5kw-160kw, has 15 models in total and they share 6 sizes. | ||||||||
Size | Model | A(mm) | B(mm) | B1(mm) | H1(mm) | W(mm) | D(mm) | Installation Hole Diameter (mm) |
2 | S300A/E-2-4T 5.5K | 70 | 338 | 5.5 | 350 | 100 | 237 | 5 |
S300A/E-2-4T 7.5K | ||||||||
3 | S300A/E-3-4T 11K | 100 | 338 | 5.5 | 350 | 142 | 237 | 5 |
S300A/E-3-4T 15K | ||||||||
4 | S300A/E-4-4T 18.5K | 120 | 338 | 5.5 | 350 | 180 | 237 | 5 |
S300A/E-4-4T 22K | ||||||||
5 | S300A/E-5-4T 30K | 150 | 338 | 5.5 | 400 | 240 | 257 | 5 |
S300A/E-5-4T 37K | ||||||||
S300A/E-5-4T 45K | ||||||||
6 | S300A/E-6-4T 55K | 200 | 590 | 12.5 | 615 | 290 | 308 | 11 |
S300A/E-6-4T 75K | ||||||||
S300A/E-6-4T 90K | ||||||||
S300A/E-6-4T 110K | ||||||||
7 | S300A/E-7-4T 132K | 200 | 1008 | 12.5 | 1003 | 310 | 308 | 11 |
S300A/E-7-4T 160K |
Samples usually packed in carton or wood box as above photos; For mass production, usually packed in carton boxes and then in wooden box.
About shipping:
Fedex/ DHL/ UPS and some fast and economic shipping, or other methods buyer appointed.
All frequency drive enjoys 18 months warranty time after sales.
Please contact us via mail or phone call if you have any questions.
Ratings | ||||||
Size | Model | Input Rated Voltage(V) | Input Rated Current(A) | Output Rated Current(A) | Adaptable Motor(kw) | Adaptable Motor(hp) |
2 | S300A/E-2-4T 5.5K | 400 | 16.7 | 13 | 5.5 | 7.5 |
S300A/E-2-4T 7.5K | 400 | 20.4 | 17 | 7.5 | 10 | |
3 | S300A/E-3-4T 11K | 400 | 25.9 | 25 | 11 | 15 |
S300A/E-3-4T 15K | 400 | 34.9 | 32 | 15 | 20 | |
4 | S300A/E-4-4T 18.5K | 400 | 38.4 | 37 | 18.5 | 25 |
S300A/E-4-4T 22K | 400 | 46.4 | 45 | 22 | 30 | |
5 | S300A/E-5-4T 30K | 400 | 61.9 | 60 | 30 | 40 |
S300A/E-5-4T 37K | 400 | 76.9 | 75 | 37 | 50 | |
S300A/E-5-4T 45K | 400 | 92 | 90 | 45 | 60 | |
6 | S300A/E-6-4T 55K | 400 | 113 | 110 | 55 | 75 |
S300A/E-6-4T 75K | 400 | 157 | 150 | 75 | 100 | |
S300A/E-6-4T 90K | 400 | 180 | 176 | 90 | 125 | |
S300A/E-6-4T 110K | 400 | 214 | 210 | 110 | 150 | |
7 | S300A/E-7-4T 132K | 400 | 256 | 253 | 132 | 200 |
S300A/E-7-4T 160K | 400 | 303 | 300 | 160 | 250 |
Reactor Selection Instruction | |||
1. Input AC/DC reactor is a necessity for 160kw or higher power VFD; and is optional for power equal and under 132kw VFD. 2. Output AC reactor is optional, can be decided accroding to final application places. | |||
Model | Input AC Reactor Model (2%) | Output AC Reactor Model | DC Reactor Model |
S300A/E-2-4T 5.5K | SAL-INPUT -0075 | SAL-OUTPUT -0075 | Not support |
S300A/E-2-4T 7.5K | SAL-INPUT -0075 | SAL-OUTPUT -0075 | Not support |
S300A/E-3-4T 11K | SAL-INPUT -0150 | SAL-OUTPUT -0150 | Not support |
S300A/E-3-4T 15K | SAL-INPUT -0150 | SAL-OUTPUT -0150 | Not support |
S300A/E-4-4T 18.5K | SAL-INPUT -0220 | SAL-OUTPUT -0220 | Not support |
S300A/E-4-4T 22K | SAL-INPUT -0220 | SAL-OUTPUT -0220 | Not support |
S300A/E-5-4T 30K | SAL-INPUT -0370 | SAL-OUTPUT -0370 | Not support |
S300A/E-5-4T 37K | SAL-INPUT -0370 | SAL-OUTPUT -0370 | Not support |
S300A/E-5-4T 45K | SAL-INPUT -0550 | SAL-OUTPUT -0550 | Not support |
S300A/E-6-4T 55K | SAL-INPUT -0550 | SAL-OUTPUT -0550 | SDL-PN -0550 |
S300A/E-6-4T 75K | SAL-INPUT -0900 | SAL-OUTPUT -0900 | SDL-PN -0900 |
S300A/E-6-4T 90K | SAL-INPUT -0900 | SAL-OUTPUT -0900 | SDL-PN -0900 |
S300A/E-6-4T 110K | SAL-INPUT -1100 | SAL-OUTPUT -1100 | SDL-PN -1100 |
S300A/E-7-4T 132K | SAL-INPUT -1320 | SAL-OUTPUT -1320 | SDL-PN -1320 |
S300A/E-7-4T 160K | SAL-INPUT -1600 | SAL-OUTPUT -1600 | SDL-PN -1600 |
Brake unit and Brake resistor | ||||
1. Brake unit is built-in for VFD power equal and under 22kw, and is not included(optional) for VFD over 22kw. 2. External brake resistor is a necessity for all VFDs. It can be selected according to brake energy and brake torque. In below form there is the minimum resistance and power value to match different model. In actual use, the brake power value must be higher than that in the form, and the selection of the braking resistor power based on braking energy. | ||||
Model | Brake Unit | Minimum Resistance (Ω) | Minimum Power(kw) | |
S300A/E-2-4T 5.5K | Built-in | 34 | 6.16*k | K refers to brake frequency. K differs in industry and below can be taken as reference. Elevator: K=10%-15% Oil pumping unit: k=10%-20% Centrifugal machine:k=5%-20% Unwinder and dewinder machine:k=50%-60% Crane: k=20%-40% Occasionally brake load:k=5%-10% |
S300A/E-2-4T 7.5K | Built-in | 34 | 8.4*k | |
S300A/E-3-4T 11K | Built-in | 34 | 12.32*k | |
S300A/E-3-4T 15K | Built-in | 34 | 16.8*k | |
S300A/E-4-4T 18.5K | Built-in | 15 | 20.72*k | |
S300A/E-4-4T 22K | Built-in | 15 | 24.64*k | |
S300A/E-5-4T 30K | Optional to built-in | 10 | 33.6*k | |
S300A/E-5-4T 37K | Optional to built-in | 10 | 41.44*k | |
S300A/E-5-4T 45K | Optional to built-in | 10 | 50.4*k | |
S300A/E-6-4T 55K | Optional to built-in | 5 | 61.6*k | |
S300A/E-6-4T 75K | Optional to built-in | 5 | 84*k | |
S300A/E-6-4T 90K | Optional to built-in | 4 | 100.8*k | |
S300A/E-6-4T 110K | Optional to built-in | 4 | 123.2*k | |
S300A/E-7-4T 132K | Optional to built-in | 2.6 | 147.84*k | |
S300A/E-7-4T 160K | Optional to built-in | 2.6 | 179.2*k |
Technical specifications | ||
Item | Specifications | |
Basic function | Output frequency | V/F control: 0-1000Hz; Vector control:0-400Hz |
Carrier frequency | 0.8kHz-12kHz, adjustable according to load feature | |
Input frequency resolution | Digital setting: 0.01Hz Simulating setting: Maximum frequency*0.025% | |
Control method | SVG,FVC, V/F control | |
Starting torque | 0.25Hz/150%(SVC), 0Hz/180%(FVC) | |
Speed adjustable range | 1:200(SVC); 1:1000(FVC) | |
Rotating speed | ±0.5%(SVC); ±0.02%(FVC) | |
Torque control accuracy | ±7.5%(SVC) (Over 5Hz); ±5%(FVC) | |
Overload capacity | 150% rated current for 60seconds | |
Torque boost | Automatical torque boost; Manual torque boost 0.1%-30.0% | |
Acceleration and deceleration curve | Linear or S-curve acceleration/deceleration mode, four types of acceleration/deceleration time, acceleration/deceleration time range 0.0s-6500.0s | |
DC braking | DC braking frequency: 0.00Hz-Maximum frequency Braking time: 0.0s-36.0s Braking current value: 0.0%-100.0% | |
Jog control | Jog control frequency range: 0.00Hz-50.00Hz Jog control acceleration and deceleration time: 0.0s-6500.0s | |
Easy PLC, speed profile | Support maximum 16 speed profiles via built in PLC or control terminaL | |
Built-in PID | Convenient to realize the process control closed-loop control system | |
AVR | Keep outpout voltage steady automatically when state grid voltage changes | |
Overvoltage and overcurrent stall speed control | Automatically limit the current and voltage during operation to prevent frequent over-current and over-voltage trips | |
Fast current limiting function | Minimize over-current breakdown and keep the normal operation of the drive | |
Torque limit and control | Crane feature. Automatically limit torque during operation to prevent over current trip.Torque control can be used in Closed loop Vector mode | |
Personalized function | Outstanding performance | To control asynchronous and synchronous motor via high performance FVC technology. |
Instantaneous outage continue work | Drive continue working for a short time in instantaneous power outage( the voltage compensation via energy feedback from load ) | |
Fast current limiting function | Avoid frequent over-current faults of the drive | |
Virtual I/O | 5 groups of virtual DI/DO, can realize simple logical control | |
Timing control | Timing control function: time setting range: 0.0min-6500.0min | |
Multithreaded bus support | Support 3 kinds fieldbus: Modbus, CANopen, Profibus | |
Drive overheat protection | Support motor temperature sensor input (PT100/KTY84), optional card supports motor temperature detection | |
Encode support | Support resolver, ABZ incremental encoder | |
Overexcitation function | It can effectively suppress the rise of bus voltage during deceleration, avoid frequent reporting of overvoltage faults, and achieve rapid braking at the same time to meet the needs of rapid shutdown after outage. | |
Wind turbine, water pumps energy saving application | With excellent motor-side output waveform, it can meet the application of multi split and long-distance applications; it can meet the application of system upgrade. | |
Flexible terminal functions | A variety of logic function options to meet the general control function requirements of general drives (more detais can refer to manual) | |
Basic function | Command source | Operation panel setting, control terminal setting, serial communication port setting, can be switched in a variety of ways |
Frequency source | 10 kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, serial port setting, can be switched in a variety of ways | |
Auxiliary frequency sources | 10 kinds of auxiliary frequency sources, which can flexibly realize auxiliary frequency fine-tuning and frequency synthesis | |
Input terminal | Standard: 7 pieces of digital input terminals, 1 of which support maximum 100KHz High speed pulse input; 3 pieces of Analog input terminals, 1 of them only support 0-10v voltage input, the other support 0-10v voltage input or 0-20mA current input, the rest 1 support -10v-10v voltage input; Expansion capacity: 2 digital input terminals, 2 orthogonal pulse signal input terminals, one analog input terminal can support PT100/KTY84 | |
Output terminal | Standard: 2 pieces of digital output terminals, 1 pieces of high speed pulse input(open collector type is optional),Support 0-100KHz square signal output; 1 piece of digital output terminal; 2 pieces of relay output terminal; 2 pieces of vitual output terminals, 1 of them support 0-20mA current output or 0-10V voltage output, the other only support 0-10v voltage input | |
Others | LED display | Parameter display |
Key locking and function selection | Realize partial or full keys locking, and can define the action scope of some keys to prevent misoperation | |
Protection function | Power-on motor short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection and other brake circuit protection functions: brake tube overload, brake tube through, brake resistance protection Features | |
Optional accessories | LED operation panel, brake package, resolver PG card, ABZ encoder PG card, Profibus communication card, CANopen communication card, IO extension card | |
Application environments | Application places | Indoors, free from direct sunlight, free of dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt, etc. |
Latitude | No derating is required for use below 1000 meters, derating 1% for every 100 meters above 1000 meters, the highest operating latitude is 3000 meters | |
Ambient temperature | -10ºC~40ºC(derate to use in 40ºC~50ºC) | |
Humidity | Less than 95%RH, no condensation | |
Vibration | Less than 5.9m/s' (0.6g) | |
Storage temperature | -20ºC~60ºC |