1. AC Frequency Inverter for motor
2. Excellent torque control and reliable brake control frequency inverter
3. Approved by ECMG, CE, ABS, TUV, ISO9000
4. Global frequency inverter supplier
With complete applications for water supply, with high efficiency, pressure stable, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages. Widely used in:
1 Domestic water for buildings, urban areas, business units, public institutions.
2 Waterworks and modern irrigation.
3 The production, domestic water supply, constant pressure water supply, etc.
4 Musical Fountain of automatic water control.
5 Various types of central air-conditioning circulation pump, cooling water supply system.
6 High-rise buildings, hotels, restaurants and other domestic water supply system.
7 Market, office buildings, commercial buildings domestic water supply system.
8 High-rise buildings hot water supply and hot water heating system.
9 Various types of oil constant pressure supply, air constant pressure supply, fan constant pressure control system, etc.
2. Excellent torque control and reliable brake control frequency inverter
3. Approved by ECMG, CE, ABS, TUV, ISO9000
4. Global frequency inverter supplier
With complete applications for water supply, with high efficiency, pressure stable, reliable, simple operation, easy installation, small footprint, low noise, no pollution, low investment, effective advantages. Widely used in:
1 Domestic water for buildings, urban areas, business units, public institutions.
2 Waterworks and modern irrigation.
3 The production, domestic water supply, constant pressure water supply, etc.
4 Musical Fountain of automatic water control.
5 Various types of central air-conditioning circulation pump, cooling water supply system.
6 High-rise buildings, hotels, restaurants and other domestic water supply system.
7 Market, office buildings, commercial buildings domestic water supply system.
8 High-rise buildings hot water supply and hot water heating system.
9 Various types of oil constant pressure supply, air constant pressure supply, fan constant pressure control system, etc.
Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Motor Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 3.5 | 6.2 | 9.2 | 14.9 | 21.5 | 27.9 | 39 | 50.3 | 60 | 69.3 | 86 | 104 | 124 | 150 | 201 | |
Braking unit | Built-in as standard | External braking unit needed | ||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Self-cooling | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |